Knowledge / Civil Engineering / Earthquake-resistant design

Earthquake-resistant design

Civil Engineering (B.E./B.Tech) · Structural analysis and design · free study notes for exams, placements and interviews

In short

Earthquake-resistant design is the practice of proportioning and detailing a structure so that it survives ground shaking without collapse, using code-specified inertia forces instead of a measured load. In India the governing documents are IS 1893 (Part 1): 2016 for criteria and loads, IS 13920: 2016 for ductile detailing of RC members, IS 4326 / IS 13828 / IS 13827 for masonry and earthen construction, and Part 6 of the National Building Code 2016. The philosophy is not "no damage" but graded performance — no damage in minor shaking, no structural damage in moderate shaking, and no collapse in the strongest shaking expected at the site. It carries 5–10 marks in GATE Civil and is a standing topic in design interviews at L&T, Tata Projects, AECOM, Jacobs, Afcons and every structural consultancy, because almost 59% of India's land area is in Zones III to V.

Explained

Ground motion, hazard and the Indian zone map

Design philosophy, seismic weight and load combinations

Methods of analysis

  1. Equivalent static (seismic coefficient) method — permitted for regular buildings up to 15 m in Zones II and III, and generally for low-rise regular buildings; base shear Vb = Ah·W distributed over height in proportion to Wi·hi².
  2. Linear dynamic analysis — mandatory for tall or irregular buildings (IS 1893: 2016 Cl 7.7 requires dynamic analysis for buildings taller than 15 m in Zones IV–V and for all irregular buildings):
    • Response spectrum method (modal analysis): 3D model, eigenvalue solution, modal mass and modal participation factors, enough modes to capture at least 90% of the total seismic mass, responses combined by SRSS (well-separated modes) or CQC (closely spaced modes).
    • Scaling rule: if the dynamic base shear is less than the base shear from the empirical-period static method, all response quantities are scaled up by the ratio. The dynamic result is never scaled down.
    • Time-history (response-history) analysis: direct integration with at least three (preferably seven) spectrum-compatible accelerograms — used for isolated, irregular, or very important structures.
  3. Nonlinear static (pushover) analysis — monotonically increasing lateral load against a capacity curve; used for performance-based assessment and retrofit design (not a design method in IS 1893, but standard practice following ATC-40/FEMA 356).
  4. Fundamental period Ta (Cl 7.6): bare RC moment frame Ta = 0.075 h0.75; composite 0.080 h0.75; steel moment frame 0.085 h0.75; for all other buildings including RC frames with masonry infill Ta = 0.09 h/√d. Buildings with RC structural walls have a separate expression using the effective wall area. Infill stiffens a frame and shortens its period, which usually increases the design force.
  5. Design spectrum (5% damping, Fig. 2 / Cl 6.4.2): Sa/g rises as 1 + 15T up to T = 0.10 s, stays at the plateau 2.50, then decays as 1.00/T (Type I rock/hard soil, from 0.40 s), 1.36/T (Type II medium soil, from 0.55 s) or 1.67/T (Type III soft soil, from 0.67 s), up to 4 s. Damping multipliers (Table 3) apply only in response spectrum/dynamic analysis — e.g. 1.40 for 2% and 0.80 for 10% damping.

Configuration, irregularities and drift control

Ductile detailing of RC — IS 13920: 2016

Masonry, foundations, soil effects and advanced systems

Key points

Formulas and examples

Design base shear: Vb = Ah × W (Vb in kN, W = seismic weight in kN)
Design horizontal seismic coefficient: Ah = (Z/2) × (Sa/g) / (R/I) [dimensionless]
Vertical coefficient: Av = (2/3) × (Z/2) × (Sa/g) / (R/I)
Vertical distribution: Qi = Vb × (Wi hi²) / Σ(Wj hj²) (hi = height of floor i above base, m)
Fundamental period: Ta = 0.075 h0.75 (bare RC MRF); Ta = 0.085 h0.75 (steel MRF); Ta = 0.09 h/√d (frames with masonry infill); h, d in m
Spectrum (5% damping): Sa/g = 2.50 on the plateau; 1.00/T (hard), 1.36/T (medium), 1.67/T (soft) in the decaying branch
Design eccentricity: edi = 1.5 esi + 0.05 bi or esi − 0.05 bi ; torsional moment = Qi × edi
Drift check: Δi / hi ≤ 0.004
Strong column–weak beam: ΣMc ≥ 1.4 ΣMb
Beam design shear (sway to right): Vu = 1.2(DL+IL)L/2 + 1.4 (Mu,Ahogging + Mu,Bsagging)/L (L = clear span, m)
Column design shear: Vu = 1.4 (Mu,beam-left + Mu,beam-right) / hst (hst = storey height, m)
Special confining reinforcement (rectangular hoop): Ash = 0.18 s h (fck/fy)[(Ag/Ak) − 1.0] ≥ 0.05 s h fck/fy (Ash mm², s = spacing mm, h = longer dimension of hoop ≤ 300 mm, Ag = gross area, Ak = confined core area, fck & fy in N/mm²)

Example 1 — Seismic weight, base shear and distribution (5-storey RC SMRF). Building 20 m × 15 m in plan, 5 storeys of 3.30 m (h = 16.5 m), Zone IV, medium soil, brick infill, residential (I = 1.0), SMRF with IS 13920 detailing (R = 5.0).

FloorWi (kN)hi (m)Wi hi²Qi (kN)Storey shear (kN)
Roof (5)240016.5653 400345.6345.6
4300013.2522 720276.5622.1
330009.9294 030155.5777.6
230006.6130 68069.1846.7
130003.332 67017.3864.0
Σ14 400—1 633 500864.0—

Example 2 — Effect of zone and of detailing (same building, Sa/g = 2.50, I = 1.0).

CaseZRAhVb (kN)
Zone II, SMRF0.105.00.025360
Zone III, SMRF0.165.00.040576
Zone IV, SMRF0.245.00.060864
Zone V, SMRF0.365.00.0901296
Zone IV, OMRF (no ductile detailing)0.243.00.1001440

Ductile detailing to IS 13920 lets the same Zone IV building be designed for 864 kN instead of 1440 kN — 40% less force, for the cost of better hoops.

Example 3 — Torsion and drift check (building of Example 1).

Example 4 — Strong column–weak beam and capacity shear. Interior joint; beams framing in have Mu = 180 kN·m (hogging) and 120 kN·m (sagging) for sway in one direction → ΣMb = 300 kN·m.

Example 5 — Special confining reinforcement. Column 400 × 600 mm, M25 concrete, hoops of Fe415, clear cover 40 mm to the hoop, s = 100 mm, single rectangular hoop so h = 300 mm (the limit).

Where it is used

Interview questions

Common mistakes

Related topics

Structural dynamics basics · Tall buildings, shear walls and lateral loads · Reinforced concrete design (IS 456) · Masonry structures · Steel structures design (IS 800) · Repair and rehabilitation of structures

Open in the Knowledge reader →Find jobs →