In short
Steam is water vapour used as the working fluid in power plants, process heating and sterilisation, and its properties cannot be found from the ideal-gas equation because water changes phase. Property values (p, T, v, u, h, s) are therefore read from steam tables or the Mollier (h-s) chart, with the dryness fraction x describing how much of a wet mixture is actually vapour. Every Rankine-cycle, boiler, turbine, condenser and heat-exchanger calculation in a university exam, in GATE, and in design work at NTPC, BHEL, L&T, Thermax, Forbes Marshall, ISGEC or any process plant begins with these numbers. It is examined as table-reading problems, dryness-fraction measurement by calorimeter, and property changes across boiling, throttling and expansion.
Explained
Formation of steam at constant pressure
Heat water at a fixed pressure and the temperature rises until it reaches the saturation temperature T_sat for that pressure; after that, temperature stops rising while the water boils.
- Subcooled (compressed) liquid: T < T_sat at that pressure. Heat added is sensible heat.
- Saturated liquid (x = 0): water just at the point of boiling; properties get subscript *f* (h_f, v_f, s_f).
- Wet steam (0 < x < 1): a mixture of saturated liquid and saturated vapour at the same p and T. Temperature alone cannot fix its state.
- Dry saturated steam (x = 1): all liquid just evaporated; properties get subscript *g*. Heat added from x = 0 to x = 1 is the latent heat of vaporisation h_fg (also called enthalpy of evaporation).
- Superheated steam: heated beyond T_sat at the same pressure. Degree of superheat = T_sup − T_sat. Now p and T are independent, so a separate superheat table is needed.
- Saturation pressure and temperature are linked one-to-one: 1 bar ↔ ~99.6 °C, 10 bar ↔ ~179.9 °C, 100 bar ↔ ~311 °C. As pressure rises h_fg falls (≈2257 kJ/kg at 1 bar, ≈1317 kJ/kg at 100 bar) and becomes zero at the critical point.
Key fixed points and the p-v, T-s pictures
- Critical point of water: ~22.064 MPa (220.64 bar), 373.95 °C, v ≈ 0.003106 m³/kg. Above it there is no distinct boiling — liquid and vapour are indistinguishable, so supercritical boilers have no drum.
- Triple point: 0.01 °C and 0.6112 kPa, where ice, water and vapour coexist. Steam-table internal energy and entropy are taken as zero for saturated liquid here (so h_f ≈ 0.0 kJ/kg).
- On a T-s or h-s diagram, the saturated-liquid and saturated-vapour lines meet at the critical point forming a dome; wet states lie inside, superheated states to the right.
- Constant-pressure lines inside the dome are horizontal on T-s (boiling is isothermal) and are straight sloping lines on h-s; outside the dome they curve upward.
- The vapour dome's apex means that near the critical point small property errors matter — one reason supercritical plants use IF-97 software rather than printed tables.
Dryness fraction and mixture properties
- Dryness fraction (quality) x = mass of dry vapour / total mass of mixture. Wetness = 1 − x. Priming/carryover is water droplets carried with steam in a boiler.
- Any specific property of wet steam is the mass-weighted average of its liquid and vapour parts: v = v_f + x·v_fg, h = h_f + x·h_fg, u = u_f + x·u_fg, s = s_f + x·s_fg (where v_fg = v_g − v_f, etc.).
- Because v_f is tiny compared with v_g at low pressure, the approximation v ≈ x·v_g is often used — acceptable below about 10 bar, poor near the critical point.
- Why x matters in practice: wet steam erodes turbine blades; steam quality below about 0.88 at the LP exhaust is avoided by reheating. Wet steam also transfers less heat per kg in a process heater.
Reading and interpolating steam tables
Standard tables used in India (as printed in most textbooks and in IS/BIS-referenced property data) follow the IAPWS-IF-97 formulation, which replaced the older 1967 IFC formulation; small third-decimal differences between textbook editions are normal and not an error. Table structure:
- Saturated steam by temperature — T, p_sat, v_f, v_g, h_f, h_fg, h_g, s_f, s_g.
- Saturated steam by pressure — same columns indexed by p (most used in power problems).
- Superheated steam — for each pressure, v, h, s against temperature.
- Compressed liquid — rarely needed; for p below ~50 bar, take h ≈ h_f at the same temperature, or h = h_f + v_f(p − p_sat).
Steps to fix a state:
- Given p and T: compare T with T_sat. T < T_sat → liquid; T = T_sat → wet (need x); T > T_sat → use superheat table.
- Given p and x: use the mixture equations above.
- Given p and h (or s): compute h_f and h_g; if h_f < h < h_g the steam is wet and x = (h − h_f)/h_fg; if h > h_g it is superheated.
- Linear interpolation between tabulated rows: y = y₁ + (y₂ − y₁)(x − x₁)/(x₂ − x₁). Interpolate in the smallest practical interval; properties vary non-linearly, so wide-interval interpolation near saturation introduces error.
- u from h: steam tables often omit u; use u = h − pv with p in kPa and v in m³/kg to get kJ/kg.
Mollier (h-s) chart and when to use it
- The Mollier chart plots enthalpy against entropy with constant-pressure, constant-temperature, constant-dryness and constant-superheat lines. Only the region of practical interest (x above ~0.5 and superheat) is drawn.
- Use: isentropic expansion in a turbine or nozzle is a vertical line down — read h₂ and x₂ directly; throttling is a horizontal line (h constant) to the right.
- Advantage: quick, visual, no interpolation. Limitation: chart-reading accuracy is only about ±1-2%, so numerical work and design use tables or IF-97 software.
- Internal energy and specific volume are not read off the chart; v comes from tables.
Measuring dryness fraction
- Barrel (bucket) calorimeter: condense a known mass of steam in a known mass of water and apply an energy balance. Simple, but heat losses make it inaccurate.
- Separating calorimeter: mechanically separates and weighs the entrained water; gives x from masses alone, but misses fine mist, so it reads high.
- Throttling calorimeter: throttles the steam to about atmospheric pressure, where it becomes superheated at constant enthalpy; measuring p₂ and T₂ fixes h₂ and hence x₁ from h₁ = h₂. Works only if the steam is dry enough (roughly x above 0.95) to become superheated after throttling.
- Combined separating-and-throttling calorimeter: the separator first removes bulk water (giving x₁), then the throttling calorimeter measures the remaining steam (x₂); the true dryness is x = x₁ × x₂. This is the standard method for very wet steam and a favourite exam question.
Properties in use: processes and standards
- Isobaric (boiler): q = h₂ − h₁ (steady flow, no work).
- Isentropic (turbine, nozzle): s₂ = s₁; w = h₁ − h₂. Real machines have isentropic efficiency, so the actual drop is less and the exit is drier.
- Throttling (valve, calorimeter): h₂ = h₁; pressure falls, entropy rises, no work, steam becomes drier or superheated — the basis of the throttling calorimeter.
- Indian practice and codes: boiler and piping work follows the Indian Boiler Regulations, 2026 (in force from October 2026, superseding the 1950 Regulations) under the Boilers Act, 2025 (in force from 1 May 2025, replacing the 1923 Act), administered by state Chief Inspectors of Boilers; BS/IS codes and IS 10496 steam-pipe sizing practice use table-based enthalpy data. Boiler efficiency testing (IS 13979 / BS 845 lines, and the BEE *Energy Manager* material under the Energy Conservation Act, 2001) uses h_steam − h_feedwater straight from steam tables.
- Typical Indian plant conditions: utility subcritical units ~ 150-170 bar, 537/565 °C; supercritical units ~ 247 bar, 565/593 °C; process boilers 10-45 bar saturated.
Key points
- Saturation temperature - the boiling temperature fixed by pressure; p and T are not independent inside the dome.
- Sensible heat h_f - heat to bring water from 0 °C to saturation at that pressure.
- Latent heat h_fg - heat to evaporate 1 kg at constant p and T; falls with pressure, zero at the critical point.
- h_g = h_f + h_fg - enthalpy of dry saturated steam.
- Dryness fraction x - mass of vapour per unit mass of mixture; x = 0 saturated liquid, x = 1 dry saturated.
- Mixture rule - any property = f-value + x × (fg difference); apply to v, u, h and s alike.
- Superheated steam - needs both p and T; degree of superheat = T − T_sat.
- Critical point - 220.6 bar, 373.95 °C; above it, no phase change and no latent heat.
- Triple point - 0.01 °C, 0.6112 kPa; datum where u_f = s_f = 0 and h_f ≈ 0.
- Enthalpy of superheated steam ≈ h_g + c_ps(T_sup − T_sat), with c_ps ≈ 2.0-2.3 kJ/kg·K.
- Throttling - constant enthalpy; raises dryness, never produces work.
- Isentropic expansion - constant entropy; work = h₁ − h₂; wetness increases down the turbine.
- Mollier chart - h-s plot for quick turbine and nozzle work; tables for accurate numbers.
- Separating + throttling calorimeter - true x = x₁ × x₂.
- u = h − pv - internal energy when the table omits it.
- Specific volume rises hugely as pressure falls (0.1944 m³/kg at 10 bar vs 14.67 m³/kg at 0.1 bar) - why LP turbine blades and condensers are large.
- IAPWS-IF-97 - the current international property formulation behind modern tables and software.
- Indian Boiler Regulations, 2026 (successor to the 1950 Regulations) under the Boilers Act, 2025 (successor to the 1923 Act), govern steam-plant practice in India.
Formulas and examples
v = v_f + x(v_g − v_f) m³/kg ; h = h_f + x·h_fg kJ/kg ; s = s_f + x(s_g − s_f) kJ/kg·K ; u = h − pv (p in kPa)
h_g = h_f + h_fg ; h_superheat ≈ h_g + c_ps(T_sup − T_sat), c_ps ≈ 2.1 kJ/kg·K
Throttling calorimeter: h_f1 + x₁h_fg1 = h₂ → x₁ = (h₂ − h_f1)/h_fg1
Separating + throttling: x = x₁ × x₂, with x₁ = m_s/(m_s + m_w)
Interpolation: y = y₁ + (y₂ − y₁)(t − t₁)/(t₂ − t₁)
Steady-flow energy: q − w = (h₂ − h₁) + (V₂² − V₁²)/2 + g(z₂ − z₁), per kg
Reference values used below (standard tables, IF-97):
| p (bar) | T_sat (°C) | v_g (m³/kg) | h_f | h_fg | h_g | s_f | s_g |
|---|---|---|---|---|---|---|---|
| 0.1 | 45.8 | 14.67 | 191.8 | 2392.8 | 2584.6 | 0.649 | 8.149 |
| 1.0 | 99.6 | 1.694 | 417.5 | 2257.9 | 2675.4 | 1.303 | 7.359 |
| 10 | 179.9 | 0.1944 | 762.8 | 2015.3 | 2778.1 | 2.138 | 6.586 |
| 40 | 250.4 | 0.04978 | 1087.3 | 1714.1 | 2801.4 | 2.797 | 6.070 |
Example 1 - properties of wet steam. Steam at 10 bar, x = 0.85.
- h = 762.8 + 0.85 × 2015.3 = 762.8 + 1713.0 = 2475.8 kJ/kg
- v = v_f + x(v_g − v_f) with v_f = 0.001127: v = 0.001127 + 0.85 × 0.19327 = 0.1654 m³/kg
- s = 2.138 + 0.85 × (6.586 − 2.138) = 2.138 + 3.781 = 5.919 kJ/kg·K
- u = h − pv = 2475.8 − 1000 × 0.1654 = 2310.4 kJ/kg
Example 2 - heat to raise steam. Feedwater at 40 °C (h ≈ 167.5 kJ/kg) is converted to dry saturated steam at 10 bar, 2 t/h.
- Heat per kg = 2778.1 − 167.5 = 2610.6 kJ/kg.
- Mass flow = 2000/3600 = 0.5556 kg/s → heat load = 0.5556 × 2610.6 = 1450.3 kW.
- With boiler efficiency 85%, fuel heat input = 1450.3/0.85 = 1706.3 kW.
Example 3 - isentropic expansion in a turbine. Dry saturated steam at 40 bar expands isentropically to 0.1 bar.
- s₁ = s_g = 6.070 kJ/kg·K = s₂ = 0.649 + x₂(8.149 − 0.649)
- x₂ = (6.070 − 0.649)/7.500 = 5.421/7.500 = 0.723 (very wet — real plants superheat and reheat)
- h₂ = 191.8 + 0.723 × 2392.8 = 191.8 + 1730.0 = 1921.8 kJ/kg
- Ideal work = 2801.4 − 1921.8 = 879.6 kJ/kg; at 85% isentropic efficiency, actual work = 747.7 kJ/kg.
Example 4 - throttling calorimeter. Steam at 10 bar is throttled to 1 bar and 120 °C. Superheated steam at 1 bar, 120 °C has h ≈ 2716.6 kJ/kg.
- h₁ = h₂ = 2716.6 → x₁ = (2716.6 − 762.8)/2015.3 = 1953.8/2015.3 = 0.9695
- Wetness = 3.05%. (The 20.4 °C of superheat after throttling confirms the instrument is valid.)
Example 5 - combined separating and throttling calorimeter. A separator drains 0.45 kg of water while 9.55 kg of steam passes on; the throttling section then gives x₂ = 0.97.
- x₁ = 9.55/(9.55 + 0.45) = 0.955; true dryness x = 0.955 × 0.97 = 0.926, i.e. 7.4% wetness.
| Method | What it measures | Range | Main limitation |
|---|---|---|---|
| Barrel calorimeter | Condensation energy balance | Any x | Large heat losses |
| Separating | Weighs separated water | Very wet steam | Misses fine mist (reads high) |
| Throttling | h constant to superheat | x > ~0.95 | Fails for wet steam |
| Combined | x₁ × x₂ | Any x | Two readings, more apparatus |
Where it is used
- Thermal power plants: NTPC, Tata Power, Adani Power — heat rate, turbine heat balance and condenser vacuum calculations all read enthalpies from tables; BHEL and L&T design boilers and turbines on them.
- Process industry: sugar, paper, textile, distillery, fertiliser and refinery plants size steam headers, PRVs and heat exchangers using h_fg at header pressure; Thermax, Forbes Marshall and ISGEC supply the boilers and steam traps.
- Energy audits: BEE-certified Energy Auditors compute boiler efficiency by the direct method (steam enthalpy rise ÷ fuel energy) and value steam loss in rupees per tonne.
- Food, pharma and hospitals: autoclave and CIP sterilisation specify dry saturated steam quality; wet or superheated steam fails sterilisation validation.
- Statutory inspection: boiler attendants and Boiler Inspectors under the Indian Boiler Regulations work with saturation pressure-temperature pairs for hydraulic tests and safety-valve settings.
- Job roles: graduate engineer trainee (thermal), performance engineer, boiler commissioning engineer, HVAC and utility engineer, energy auditor.
Interview questions
- Q: Why can't the ideal-gas equation be used for steam? A: Steam near saturation is close to condensation, so intermolecular forces and phase change make pv = mRT badly wrong; property tables or IF-97 correlations are used instead.
- Q: What is dryness fraction and why does it matter in a turbine? A: It is the mass fraction of vapour in wet steam; low dryness at the LP stages causes blade erosion and efficiency loss, which is why reheat is used.
- Q: How many properties fix the state of wet steam, and of superheated steam? A: Wet steam needs pressure (or temperature) plus dryness fraction; superheated steam needs pressure and temperature, which are independent there.
- Q: What happens to latent heat as pressure rises? A: It decreases steadily and becomes zero at the critical point, 220.6 bar and 373.95 °C.
- Q: Why does throttling make wet steam drier? A: Enthalpy stays constant while pressure falls, and h_f falls faster than the enthalpy available, so more of the mixture must be vapour; it is an irreversible process with rising entropy.
- Q: Why can a throttling calorimeter not measure very wet steam? A: Its reading needs the steam to be superheated after throttling; below about x = 0.95 the exit is still wet, so a separating stage is added first.
- Q: What is the significance of the triple point in steam tables? A: It is the datum — internal energy and entropy of saturated liquid are set to zero at 0.01 °C — so tabulated values are relative, not absolute.
- Q: Difference between superheated steam and supercritical steam? A: Superheated steam is above T_sat at a pressure below critical, so it was formed by boiling; supercritical fluid is above 220.6 bar, where no boiling or distinct phases occur.
- Q: Why is saturated steam preferred for process heating but superheated for turbines? A: Saturated steam gives a high film coefficient and isothermal condensation heat transfer; superheat avoids wetness in a turbine and adds usable enthalpy drop.
- Q: How do you find internal energy if the table gives only h? A: u = h − pv, with p in kPa and v in m³/kg, giving kJ/kg.
- Q: What does a vertical line on the Mollier chart represent? A: Isentropic expansion or compression — the basis of turbine and nozzle ideal-work calculations.
- Q: At 1 bar, how much more heat does evaporating water need than heating it from 0 °C? A: About 2258 kJ/kg of latent heat against roughly 418 kJ/kg of sensible heat — over five times as much, which is why condensing steam is such an effective heating medium.
Common mistakes
- Treating temperature and pressure as independent inside the vapour dome, or looking up a wet state in the superheat table.
- Using h_g when the steam is wet, which overstates enthalpy by (1 − x)·h_fg.
- Forgetting v_f in v = v_f + x·v_fg at high pressure, where it is no longer negligible.
- Mixing units: p in bar with v in m³/kg in u = h − pv (must convert to kPa), or kJ/h with kW.
- Interpolating over a wide pressure range, or interpolating across the saturation line.
- Reporting the separating-calorimeter value alone as the dryness fraction instead of x₁ × x₂.
- Assuming superheated steam is always better — in a heat exchanger its low heat-transfer coefficient means a larger surface area.