Drip and sprinkler irrigation are pressurised (micro and overhead) irrigation methods that deliver water through pipes directly to the crop instead of flooding the land, raising field application efficiency from about 40-60% in surface irrigation to 70-80% (sprinkler) and 85-95% (drip). They matter because India uses roughly 80-85% of its usable water in agriculture and groundwater is over-exploited in large parts of Punjab, Haryana, Rajasthan, Gujarat, Maharashtra and Tamil Nadu. The topic carries steady marks in Agricultural Engineering university exams and in GATE (AG) under Soil and Water Conservation Engineering, usually as design problems on system capacity, uniformity, application rate and pump power. It is examined and used in jobs with Jain Irrigation, Netafim India, Finolex Plastro, Premier Irrigation, EPC Industries, Mahindra EPC, state Micro Irrigation / Horticulture Missions, NABARD-funded projects, ICAR institutes (IARI, CIAE Bhopal, ICAR-IIWM) and in AE/AEE recruitment for state water resources and agriculture departments.

Explained

Classification and basic definitions

Drip irrigation: components and working

  1. Head control unit at the pump: non-return valve, pressure gauges, filters, fertigation unit, air-release valve, flow meter, pressure regulator.
  2. Filtration (the single most important component): hydrocyclone / sand separator for sand in well water; media (gravel-sand) filter for algae and organic matter in canal or pond water; screen filter (typically 100-200 mesh, commonly 120 mesh) and disc filter as the final guard. Rule of thumb: filter openings must be 1/8 to 1/10 of the emitter passage diameter. Filters are back-flushed when the pressure drop across them rises by about 0.5 kg/cm².
  3. Mainline and submains (rigid PVC or HDPE, usually buried), laterals (12 mm or 16 mm LDPE/LLDPE on the surface along crop rows), emitters/drippers.
  4. Emitter types by flow path: long-path (microtube, labyrinth), orifice, vortex, and pressure-compensating (PC) emitters with a flexible diaphragm that holds discharge nearly constant over a pressure range — essential on undulating land. By mounting: online (punched into the lateral, 2/4/8 L/h, for orchards) and inline (built into the pipe at fixed spacing, for row crops and vegetables).
  5. Working: water at 1.0-2.5 kg/cm² at the head reaches each emitter at about 0.7-1.5 kg/cm² and drips at 1-8 L/h, keeping the root-zone soil near field capacity continuously. Only a fraction of the land (30-70%) is wetted, so evaporation, deep percolation and weed growth fall.
  6. Fertigation: water-soluble fertilizers injected by venturi injector (cheap, causes head loss), fertilizer tank (bypass, dilution not uniform) or piston/diaphragm injection pump (accurate, costliest). Advantages: 25-40% fertilizer saving, split doses matched to crop stage, no leaching below roots. Never inject phosphatic fertilizer with hard water (calcium phosphate precipitates); use urea, MOP, KNO₃, urea phosphate, 19:19:19.
  7. Clogging — the main failure mode. Physical (sand, silt), biological (algae, slime, bacteria, roots entering SDI emitters) and chemical (CaCO₃, iron and manganese oxides). Remedies: proper filtration; chlorination (continuous 1-2 ppm free chlorine, or shock dose of about 10-30 ppm for 30-60 minutes); acid treatment (dilute HCl or phosphoric acid to bring line pH to about 4 for 30-60 minutes, then flush); flushing lateral ends weekly; vacuum breakers and root-intrusion-resistant emitters for SDI.
  8. Water quality hazard (Bucks-Nakayama style criteria): low hazard if suspended solids below about 50 ppm, EC below 0.8 dS/m, pH 5-7, iron/manganese below 0.1 ppm, bicarbonate below 100 ppm; severe above roughly 100 ppm solids, pH above 8, Fe/Mn above 1.5 ppm.

Drip design procedure (as asked in exams)

  1. Crop water requirement at peak: ETc = ET₀ × Kc, or pan method Ep × Kp × Kc.
  2. Volume per plant per day = canopy (or plant spacing) area × ETc × wetted-area factor, divided by emission efficiency (0.85-0.95).
  3. Choose emitter discharge and number per plant from soil texture (sandy soils need more, closer emitters; clayey soils fewer).
  4. Operating time = volume per plant ÷ (number of emitters × emitter discharge).
  5. Lateral and submain layout: laterals along contours wherever possible; limit emitter flow variation qvar = (qmax − qmin)/qmax to 10%, which permits about 20% pressure variation in a subunit (because q varies as hˣ with x ≈ 0.5 for turbulent-flow emitters).
  6. Hydraulics: friction in a lateral with many outlets = friction for full flow over full length × Christiansen's F factor. Add or subtract elevation head.
  7. Divide the field into subunits/zones so that pump discharge and head stay reasonable; fix pump and prime mover.
  8. Check uniformity (EU or statistical uniformity) and accept if EU ≥ 90% for new systems on level land (≥ 85% on slopes).

Sprinkler irrigation: components, working and design

Comparison, advantages and limitations

Indian standards, schemes and practice

Key points

Formulas and examples

ETc = ET₀ × Kc (mm/day); pan method ETc = Ep × Kp × Kc — Ep = pan evaporation (mm/day), Kp = pan coefficient (≈ 0.7), Kc = crop coefficient
Volume per plant per day V = A_p × ETc × Wp / Ea (L/day) — A_p = plant/canopy area (m²), Wp = wetted-area fraction, Ea = emission efficiency (fraction); 1 mm over 1 m² = 1 litre
Operating time t = V / (n_e × q) (h) — n_e = emitters per plant, q = emitter discharge (L/h)
Emitter discharge q = k hˣ — h = pressure head (m), k = constant, x = emitter exponent
Emitter flow variation qvar = (q_max − q_min)/q_max × 100 (%)
Emission uniformity EU = 100 × (q̄_lowest quarter / q̄); design EU = 100 (1 − 1.27 CV/√n_e)(q_min/q̄)
Christiansen's uniformity coefficient CU = 100 [1 − Σ|xᵢ − x̄| / (n x̄)] — xᵢ = catch-can depths
Sprinkler application rate I = 3600 q_s / (S_m × S_l) (mm/h) with q_s in L/s, or I = q_s(L/h)/(S_m × S_l in m²)
Nozzle discharge q = Cd · a · √(2gH) — Cd ≈ 0.95-0.98, a = nozzle area (m²), H = nozzle head (m)
Net depth d_net = (θ_fc − θ_mad) × D_root × P_w (mm, θ volumetric fractions, D_root in mm, P_w = wetted fraction); d_gross = d_net / Ea
System capacity Q = 10 × A × d_net / (F × H × Ea) (m³/h) — A in ha, d_net in mm, F = irrigation interval (days), H = operating hours/day
Hazen-Williams hf = 10.67 L Q1.852 / (C1.852 D4.87) (m; Q in m³/s, D and L in m, C ≈ 130-150 for plastic pipe)
Lateral friction with m outlets: hf_lateral = hf(full flow) × F, where F = 1/(n+1) + 1/(2m) + √(n−1)/(6m²), n = velocity exponent (1.852 for Hazen-Williams, 2 for Darcy-Weisbach)
Pump power P = ρ g Q H / (1000 × η_pump) (kW); 1 hp = 0.746 kW; input kW = P / η_motor

Example 1 — Drip design for a mango orchard. Spacing 5 m × 5 m, canopy diameter 3 m, pan evaporation 8 mm/day, Kp = 0.7, Kc = 0.8, emission efficiency 0.90, four 4 L/h online emitters per tree.

Example 2 — Emitter exponent and uniformity. A dripper gives 4.0 L/h at 10 m head and 5.6 L/h at 20 m head.

Example 3 — Sprinkler application rate and set time. Sprinkler discharge 1,200 L/h, spacing 12 m × 12 m, net depth required 50 mm, Ea = 75%, loam soil with basic infiltration 10 mm/h.

Example 4 — Pump and motor for the above sprinkler system. Q = 16.8 m³/h = 0.00467 m³/s. Nozzle pressure 2.5 kg/cm² = 25 m, suction lift 6 m, pipe and fitting friction 7 m, riser 2 m → total head H = 40 m.

Example 5 — Lateral friction loss with the F factor. 16 mm LDPE lateral (inner diameter 14 mm), 60 m long, 30 inline emitters at 2 m spacing, each 4 L/h, C = 140.

FeatureDripSprinklerSurface (furrow/basin)
Application efficiency85-95%70-80%40-60%
Operating pressure1.0-2.5 kg/cm²2.0-4.0 kg/cm²Gravity
Discharge per outlet1-8 L/h0.3-3 L/sStream in channel
Land wetted30-70%100%100%
Energy costLowHighLowest
Suitable cropsWide-spaced, high-value, row cropsClose-growing field crops, fodderRice, wheat, most field crops
Saline waterUsable with carePoor (leaf burn)Needs leaching
Capital cost per ha (indicative)₹60,000-1,20,000₹20,000-45,000Low
Main problemCloggingWind drift, evaporationRunoff, percolation, labour

Where it is used

Interview questions

Common mistakes

Related topics