Knowledge / Environmental Science / Renewable energy

Renewable energy

Environmental Science (B.Sc) · Environmental management · free study notes for exams, placements and interviews

In short

Renewable energy is energy drawn from flows that are replenished on a human timescale - sunlight, wind, flowing water, biomass, geothermal heat and ocean energy - as against fossil fuels, which are stocks. For an environmental manager it is the main supply-side mitigation lever: it cuts CO₂ and local air pollutants per unit of useful energy and is the cheapest new generation in India today. India has crossed 50% of its installed electricity capacity from non-fossil sources (2025) against a target of 500 GW non-fossil capacity by 2030, so project appraisal, resource assessment and compliance work is growing fast. The topic is examined in B.Sc Environmental Science (energy resources and environmental management papers), in UGC-NET/GATE-ES style questions on CUF, Betz limit and energy payback, and is asked in interviews at solar/wind developers, EPC firms, ESG consultancies and state energy development agencies.

Explained

Definitions, classification and the resource base

Solar energy - resource, devices and systems

Wind, hydro and ocean energy

Bioenergy and green hydrogen

Indian policy, law and institutions

Environmental and social impacts, and limitations

Key points

Formulas and examples

PV energy output: E = Pp × H × PR, where Pp = installed peak capacity (kWp), H = annual *peak sun hours* (kWh/m²/day × 365, equivalent full-sun hours), PR = performance ratio (dimensionless)
CUF (%) = [E (kWh) / (P (kW) × 8,760)] × 100 - use 8,784 for a leap year
Fill factor FF = (Vmp × Imp) / (Voc × Isc); module efficiency η = Pmax / (A × 1,000 W/m²)
Wind power P = ½ ρ A v³ Cp, ρ = air density (≈1.225 kg/m³ at 15 °C, sea level), A = swept area = πD²/4 (m²), v = wind speed (m/s), Cp = power coefficient (≤16/27)
Hydro power P = ρ g Q H η, ρ = 1,000 kg/m³, g = 9.81 m/s², Q = discharge (m³/s), H = net head (m), η = overall efficiency
Biogas energy = V (m³) × CV (MJ/m³); typical cattle dung yield 0.03-0.04 m³ of gas per kg of fresh dung
Levelised cost of energy LCOE = (CRF × Capex + annual O&M) / annual energy, with CRF = i(1+i)ⁿ / [(1+i)ⁿ − 1], i = discount rate, n = life in years
Simple payback (years) = net capital cost / annual saving; CO₂ avoided = E (MWh) × grid emission factor (≈0.71-0.73 tCO₂/MWh for the Indian grid, CEA database - revised yearly)
Degradation: output in year n = Year-1 output × (1 − d)n−1, d = annual degradation (~0.5%/yr for crystalline silicon)

1. Rooftop solar - generation, subsidy and payback. A 5 kWp rooftop system in Delhi, CUF 16%, retail tariff ₹8/kWh, installed cost ₹2.5 lakh.

2. Wind turbine power and the Betz limit. Rotor diameter 100 m, wind 8 m/s, ρ = 1.225 kg/m³.

3. Small hydro scheme. Q = 2 m³/s, net head 40 m, turbine-generator efficiency 85%.

4. LCOE of a utility solar plant. 100 MW, capex ₹400 crore, O&M ₹4 lakh/MW/yr, i = 9%, n = 25 years, CUF 20%.

5. Family biogas plant. Five cattle giving 50 kg of fresh dung a day, yield 0.04 m³/kg, biogas CV 20 MJ/m³.

SourceTypical Indian CUFLand / resource needDispatchable?Main environmental concern
Solar PV (utility)17-21%2-2.5 ha/MWNo (unless stored)Land use, module waste, cleaning water
Wind (onshore)20-35%Low (turbine pads only)NoBirds/bats, noise, blade disposal
Small hydro35-50%Site-specificPartlyFlow alteration, fish passage
Biomass / bagasse50-70%Large fuel catchmentYesPM and NOx emissions, fuel supply
Biogas / CBG60-80%Feedstock dependentYesSlurry and odour management
Large hydro30-45%Reservoir submergenceYesDisplacement, sediment, methane

Where it is used

Interview questions

Common mistakes

Related topics

Environmental impact assessment · Climate change and carbon accounting · ESG and sustainability reporting · Environmental laws in India · Waste management rules: plastic, e-waste and biomedical · Environmental monitoring and analysis

Open in the Knowledge reader →Find jobs →